Floor level 3 compartment or drain board food prep sink sink leg drain line from sink minimum 4 to 2 reducer air break to sewer indirect drain connection using one reducer.
Indirect plumbing connection floor drain.
Shall not exceed 15 feet 4572 mm.
Homes can either have a direct plumbing system or an indirect plumbing system.
A cistern is a tank for storing water.
For walk in coolers floor drains shall be permitted to be connected to a separate drainage line discharging into an outside receptor.
Square or circular to suit floor finish.
Indirect plumbing systems are found in most homes.
Indirect waste piping shall discharge into the building drainage system through an air gap or air break as set forth in this code.
Bolt on funnel for indirect drain waste pipes such as condensate discharge.
An indirect waste is a drainage piping that runs from a plumbing fixture or appliance and discharges into a separate waste pipe or receptacle.
802 1 2 floor drains in food storage areas.
Where a drainage air gap is required by this code the minimum vertical distance as measured from the lowest point of the indirect waste pipe or the fixture outlet to the flood level rim of the receptor shall be not less than 1 inch 25 4 mm.
Indirect drain connection using three reducers note.
The water distribution air gap is defined in chapter 6 and determined by table 603 3 1 see figure 801 2b.
Membrane clamp ring for sub surface waterproof layer.
An air break simply requires that there be no direct physical connection between the fixture indirect waste pipe and the receptor see figure 801 2a.
The image on the left shows an indirect drain going through a building wall to the exterior this type of drain may go into a septic system dry well or a municipal storm sewer.
Discharge through an indirect waste pipe by means of an air gap.
To some degree the name defines its function.
Nonetheless you need context to understand its main purpose.
The drainage air gap is not the same as the water distribution air gap.
Indirect waste indirect drain.
Removable bottle trap for use with untrapped drain bodies or direct connection gratings.
Indirect waste pipe for icemaking machines shall be not less than the drain on the unit and in no case less than 3 4 of an inch 20 mm.
This method may be allowed on a case by case basis.
In this kind of plumbing system the rising main feeds the cold water cistern as well as the kitchen tap.
Floor drains located within walk in refrigerators or freezers in food service and food establishments shall be indirectly connected to the sanitary drainage system by means of an air gap.
The compartments must be drained slowly to reduce splash.